<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Pump Control Panels &#8211; Mac 3 UK</title>
	<atom:link href="https://mac3uk.com/product-category/pump-control-panels/feed/" rel="self" type="application/rss+xml" />
	<link>https://mac3uk.com</link>
	<description>Water meets Technology</description>
	<lastBuildDate>Tue, 06 Aug 2024 14:55:40 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<!--Theme by MyThemeShop.com-->
	<item>
		<title>DIN Rail Mounted Pump Sequencer</title>
		<link>https://mac3uk.com/product/din-rail-mounted-pump-sequencer/</link>
				<pubDate>Wed, 07 Nov 2018 16:11:49 +0000</pubDate>
		<dc:creator><![CDATA[Javier Senra]]></dc:creator>
		
		<guid isPermaLink="false">https://mac3uk.com/?post_type=product&#038;p=522</guid>
				<description><![CDATA[<p>Mac3 Sequencer is a DIN rail mounted device which balances the run-time of 2 or 3 pumps in a duty standby/assist configuration depending on model.<br />
Pumps are alternated during normal usage, but allows the controller to activate both pumps together if there is a sudden demand.<br />
<em>Please note that the Sequencer is not supplied with a pressure switch or float switch. Please call to discuss the available options when ordering.</em></p>
<p> <i class="fa fa-download"></i>User Manual - PDF</p>
<p> <i class="fa fa-download"></i>Brochure Secuencer 1&#38;2 - PDF<br />
 <i class="fa fa-download"></i>Brochure Secuencer 3 - PDF</p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/din-rail-mounted-pump-sequencer/">DIN Rail Mounted Pump Sequencer</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></description>
								<content:encoded><![CDATA[<h4><i class="fa fa-wrench"></i> Application</h4>
<p>Mac3 Sequencer is a DIN rail mounted device which balances the run-time of 2 or 3 pumps depending on model in a duty-standby/assist configuration.<br />
Pumps are alternated during normal usage, but allows the controller to activate both pumps together if there is a sudden demand.<br />
The Sequencer can be deployed with a single pressure switch and float switch, or with two pressure switches and a float switch. The twin pressure switch solution allows the one pressure switch to function for regular pump control, while the second acts as an‘emergency switch’ allowing both pumps to be activated together when demand cannot be met by a single pump.</p>
<p>The sequencer is available in different models:</p>
<ul>
<li><strong>Sequencer</strong> &#8211; In rail mounted device which balances the run-time or 2 pumps in a duty-standby/assist configuration.</li>
<li><strong>Sequencer 2</strong> &#8211; Is has the same characteristics and functionality as the sequencer with the added LED&#8217;s for visualising faults.</li>
<li><strong>Sequencer 2q</strong> &#8211; It has the same characteristics and functions as the sequencer with the addition of a panel containing two switches for pump operation and seven LED diodes that always show the system status.</li>
</ul>
<p>Note: The above models Tare with either 24Vac or 110/230Vac supply (no 24vdc version is available) &#8211; please see brochure. They provide pressure/level switch inputs at 2vac and optional float switch at 24vdc to enhance safety.</p>
<ul>
<li><strong>Sequencer 3</strong> &#8211; Advanced version of the sequencer that drives groups up to 3 pumps. Interface with LED&#8217;s and control buttons.</li>
</ul>
<h4><i class="fa fa-plus"></i> Advantages</h4>
<ul>
<li>Pumps are alternated during normal usage, but allows the controller to activate both pumps together if there is a sudden demand.</li>
<li>Emptying or Filling functions.</li>
<li>DIN rail mounted device.</li>
</ul>
<h4><i class="fa fa-thumbs-up"></i> Benefits</h4>
<ul>
<li>Ideal for OEM integration or control panel building</li>
<li>Alternately Chooses Between 2 Connected Pumps (Pump Alternation) When an Input Switch is Closed</li>
<li>Duty Assist Input Activates Both Outputs Simultaneously</li>
<li>Can be used with Pressure or Level Based Controls</li>
<li>24V and 117-230V versions</li>
</ul>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/din-rail-mounted-pump-sequencer/">DIN Rail Mounted Pump Sequencer</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></content:encoded>
										</item>
		<item>
		<title>DIN Rail Mounted Level Controller &#8211; Sensopress</title>
		<link>https://mac3uk.com/product/din-rail-mounted-level-controller-sensopress/</link>
				<pubDate>Tue, 04 Sep 2018 13:11:56 +0000</pubDate>
		<dc:creator><![CDATA[Jim]]></dc:creator>
		
		<guid isPermaLink="false">https://mac3uk.com/?post_type=product&#038;p=374</guid>
				<description><![CDATA[<p>Mac3 Sensopress is a programmable, DIN rail-mounted level controller ideal for integration with OEM and panel-built products.</p>
<p>For use in Clean Water or Liquid Food Products.</p>
<p><strong>A pressure probe is not included (contact us for options).</strong></p>
<p> User Manual - PDF</p>
<p><i class="fa fa-download"></i> Brochure - PDF</p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/din-rail-mounted-level-controller-sensopress/">DIN Rail Mounted Level Controller &#8211; Sensopress</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></description>
								<content:encoded><![CDATA[<h4><i class="fa fa-wrench"></i> Application</h4>
<p>Mac3 Sensopress is a programmable, DIN rail mounted level controller and is ideal for integration with OEM and panel built products.</p>
<p>Sensopress measures the level of liquid in a tank or reservoir using a high accurate pressure sensor which detects the weight of fluid above it. Pumps and valves can be controlled to fill, empty or maintain levels by Sensopress based on the reading of a single sensor with no mechanical movement.</p>
<p>Sensopress avoids the need for technicians to accurately set floats or sensors at various heights within the tank in order to operate pumps and valves at the right levels. All levels and functions can be precisely set from the control panel.</p>
<p>Sensopress can function with any liquid using a probe and can be manually calibrated to accept probes of different ranges.</p>
<p>Sensopress is available in single channel and multi-channel models. The single channel model is supplied with a single output for controlling one external appliance, whereas the multi-channel is supplied with 4 outputs.</p>
<p>Each output channel operates independently and may overlap in range.</p>
<h4><i class="fa fa-plus"></i> Advantages</h4>
<p>The supplied level sensor is suitable for clean water and liquid food products. However, Sensopress can function with any liquid using either an alternative probe and can be manually calibrated to accept probes of different ranges.</p>
<h4><i class="fa fa-thumbs-up"></i> Benefits</h4>
<ul>
<li>DIN rail mounted.</li>
<li>Ideal for OEM systems and panel building.</li>
<li>Measures level by pressure sensing</li>
<li>Change all level settings from the control panel</li>
<li>Available with 1 or 4 outputs</li>
<li>Suitable for use in clean water or liquid food products</li>
</ul>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/din-rail-mounted-level-controller-sensopress/">DIN Rail Mounted Level Controller &#8211; Sensopress</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></content:encoded>
										</item>
		<item>
		<title>DIN Rail Mounted Level Controller &#8211; Sensitivity Options &#8211; Electroprobe Q</title>
		<link>https://mac3uk.com/product/din-rail-mounted-level-controller-sensitivity-options-electroprobe-q/</link>
				<pubDate>Tue, 04 Sep 2018 10:15:16 +0000</pubDate>
		<dc:creator><![CDATA[Jim]]></dc:creator>
		
		<guid isPermaLink="false">https://mac3uk.com/?post_type=product&#038;p=369</guid>
				<description><![CDATA[<p>DIN rail mounted (3DIN, 54mm) conductivity probe level controller.</p>
<p>Available for various supply voltages from 12 to 415V AC and DC.</p>
<p> <i class="fa fa-download"></i>User Manual - PDF</p>
<p> <i class="fa fa-download"></i>Brochure - PDF</p>
<h2>Electroprobe Overview Video</h2>
<p><iframe src="https://www.youtube.com/embed/mnOVlX-Xh3A" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/din-rail-mounted-level-controller-sensitivity-options-electroprobe-q/">DIN Rail Mounted Level Controller &#8211; Sensitivity Options &#8211; Electroprobe Q</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></description>
								<content:encoded><![CDATA[<h4><i class="fa fa-wrench"></i> Application</h4>
<p>DIN rail mounted (3DIN, 54mm) conductivity probe level controller. Available for various supply voltages from 12 to 415V AC and DC.</p>
<p>Mac3 Electroprobe Q is a multifunctional level controller with 1 fixed function. The Differential Fill/Drain Function, activates a relay output to maintain the level between two probes set at different heights. The relay only changes state when either the upper probe becomes immersed or the lower probe becomes dry, allowing the water level to move between but not exceed the area between the two level probes.</p>
<p>3 conductivity probes are used, a common electrode is always immersed and 2 electrodes above this level form low and high set points allowing Electroprobe Q to maintain a the level within a specific range.</p>
<p>Electroprobe Q is commonly used with water and other fluids with dependable conductivity, there are 3 main models available:</p>
<ul>
<li><strong>NS &#8211; Normal Sensitivity</strong> &#8211; For clean water and fluids with a maximum total resistance of 5.6KΩ. This unit will tolerate very long probe cable lengths of up to 1000m</li>
<li><strong>AS &#8211; High Sensitivity</strong> &#8211; For fluids with low conductivity, particularly rainwater, with total resistance of 68KΩ.</li>
<li><strong>SR &#8211; Adjustable Sensitivity</strong> &#8211; For fluids of unknown resistance. Adjustable between 0 and 100KΩ.</li>
</ul>
<h4><i class="fa fa-plus"></i> Advantages</h4>
<ul>
<li>Some models are multi-voltage.</li>
<li>Emptying or Filling functions.</li>
<li>No accessible controls which avoid unauthorised adjustment.</li>
</ul>
<h4><i class="fa fa-thumbs-up"></i> Benefits</h4>
<ul>
<li>Ideal for OEM integration or control panel building</li>
<li>Uses conductivity probes with no moving parts</li>
<li>Fill or drain between 2 probes points</li>
<li>Suitable for a variety of conductive liquids</li>
<li>From 12V to 415V</li>
<li>3 probe sensitivity ranges including adjustable sensitivity (SR models)</li>
<li>Non-voltage relay outputs rated 250VAC 5A(AC1) 2A(AC3)</li>
</ul>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/din-rail-mounted-level-controller-sensitivity-options-electroprobe-q/">DIN Rail Mounted Level Controller &#8211; Sensitivity Options &#8211; Electroprobe Q</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></content:encoded>
										</item>
		<item>
		<title>DIN Rail Mounted Level Controller &#8211; Electroprobe Z</title>
		<link>https://mac3uk.com/product/din-rail-mounted-level-controller-electroprobe-z/</link>
				<pubDate>Tue, 04 Sep 2018 08:07:52 +0000</pubDate>
		<dc:creator><![CDATA[Jim]]></dc:creator>
		
		<guid isPermaLink="false">https://mac3uk.com/?post_type=product&#038;p=362</guid>
				<description><![CDATA[<p>DIN rail mounted (2DIN, 35mm) conductivity probe level. Available for various supply voltages from 12 to 415Vac.</p>
<p>Single or Double Voltage Supply (Z8 or Z11 models).</p>
<p>Models available with Octal or Undecal DIN Sockets, can be replaced in seconds.</p>
<p> <i class="fa fa-download"></i>User Manual - PDF</p>
<p> <i class="fa fa-download"></i>Brochure - PDF</p>
<h2>Electroprobe Overview Video</h2>
<p><iframe src="https://www.youtube.com/embed/mnOVlX-Xh3A" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/din-rail-mounted-level-controller-electroprobe-z/">DIN Rail Mounted Level Controller &#8211; Electroprobe Z</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></description>
								<content:encoded><![CDATA[<h4><i class="fa fa-wrench"></i> Application</h4>
<p>DIN rail mounted (2DIN, 35mm) conductivity probe level controller. Available for various supply voltages from 12 to 415Vac.</p>
<p>Electroprobe Z is a multifunctional level controller with 1 fixed function. The Differential Fill/Drain Function, activates a relay output to maintain the level between two probes set at different heights. The relay only changes state when either the upper probe becomes immersed or the lower probe becomes dry, allowing the water level to move between but not exceed the area between the two level probes.</p>
<p>3 conductivity probes are used, a common electrode is always immersed and 2 electrodes above this level form low and high set points allowing Electroprobe Z to maintain a the level within a specific range.</p>
<p>Electroprobe Z is commonly used with water and other fluids with dependable conductivity, there are 3 main models available.</p>
<ul>
<li><strong>NS &#8211; Standard Sensitivity</strong> &#8211; For clean water and fluids with a maximum total resistance of 5.6KΩ. This unit will tolerate very long probe cable lengths of up to 1000m</li>
<li><strong>AS &#8211; High Sensitivity</strong> &#8211; For fluids with low conductivity, particularly rainwater, with total resistance of 68KΩ.resistance of 68KΩ. This Model will tolerate probe cable lengths of up to 80m</li>
<li><strong>SR &#8211; Adjustable Sensitivity</strong> &#8211; For fluids of unknown resistance. Adjustable between 0 and 100KΩ.This Model will tolerate probe cable lengths of up to 70m</li>
</ul>
<h4><i class="fa fa-plus"></i> Advantages</h4>
<ul>
<li>All models are multi-voltage.</li>
<li>Single or Double Voltage Supply (Z8 or Z11 models)</li>
<li>Models available with Octal or Undecal DIN Sockets, can be changed in seconds</li>
</ul>
<h4><i class="fa fa-thumbs-up"></i> Benefits</h4>
<ul>
<li>Ideal for OEM integration or control panel building</li>
<li>Uses conductivity probes with no moving parts</li>
<li>Fill or drain between 2 levels</li>
<li>Suitable for a variety of conductive liquids</li>
<li>12V to 415V Supply</li>
<li>3 probe sensitivity ranges including Adjustable probe sensitivity (SR models)</li>
<li>Non-voltage relay outputs rated 250VAC 5A(AC1) 2A(AC3)</li>
</ul>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/din-rail-mounted-level-controller-electroprobe-z/">DIN Rail Mounted Level Controller &#8211; Electroprobe Z</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></content:encoded>
										</item>
		<item>
		<title>DIN Rail Mounted Level Controller with Adjustable Sensitivity and Time Delay &#8211; Electroprobe EV</title>
		<link>https://mac3uk.com/product/din-rail-mounted-level-controller-with-adjustable-sensitivity-and-time-delay-electroprobe-ev/</link>
				<pubDate>Tue, 04 Sep 2018 06:42:34 +0000</pubDate>
		<dc:creator><![CDATA[Jim]]></dc:creator>
		
		<guid isPermaLink="false">https://mac3uk.com/?post_type=product&#038;p=355</guid>
				<description><![CDATA[<p>DIN rail mounted (4DIN, 76mm) conductivity probe level controller with adjustable sensitivity and time delay.</p>
<p>Available for various supply voltages from 24, 117 and 230V AC.</p>
<p> <i class="fa fa-download"></i>User Manual - PDF</p>
<p> <i class="fa fa-download"></i>Brochure - PDF</p>
<h2>Electroprobe Overview Video</h2>
<p><iframe src="https://www.youtube.com/embed/mnOVlX-Xh3A" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/din-rail-mounted-level-controller-with-adjustable-sensitivity-and-time-delay-electroprobe-ev/">DIN Rail Mounted Level Controller with Adjustable Sensitivity and Time Delay &#8211; Electroprobe EV</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></description>
								<content:encoded><![CDATA[<h4><i class="fa fa-wrench"></i> Application</h4>
<p>DIN rail mounted (4DIN, 76mm) conductivity probe level controller with adjustable sensitivity and time delay. Available for various supply voltages from 12 to 415V AC and DC.</p>
<p>Mac3 Electroprobe EV is a family of DIN rail mounted level controllers. Electroprobe EV operates between 2 level probes set at different levels within the tank, plus a common probe (always immersed). The output relay is activated when water touches the upper probe, and de-activated when the lower probe becomes dry. Below both these probes a common probe provides a constant sensing connection back to the controller.</p>
<p>The following features are available in various models of Electroprobe EV:</p>
<ul>
<li><strong>Differential Fill/Drain function</strong> &#8211; Activates a relay output to maintain the level between 2 probes set at different heights.</li>
<li><strong>Adjustable Sensitivity</strong> up to 100Kohm, suitable for water of low conductivity such as rainwater.</li>
</ul>
<h4><i class="fa fa-plus"></i> Advantages</h4>
<ul>
<li>All models are multi-voltage.</li>
<li>Time Delay of 0-16 seconds available on some models.</li>
<li>Emptying or Filling functions.</li>
</ul>
<h4><i class="fa fa-thumbs-up"></i> Benefits</h4>
<ul>
<li>Ideal for OEM integration or control panel building</li>
<li>Uses conductivity probes with no moving parts</li>
<li>Fill or drain between 2 probes points</li>
<li>24, 117, 230 and 380-415VAC Supply</li>
<li>Adjustable probe sensitivity (0-100KΩ)</li>
<li>Single or Double pole non-voltage relay outputs</li>
<li>Non-voltage relay outputs rated 250VAC 5A(AC1) 2A(AC3)</li>
</ul>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/din-rail-mounted-level-controller-with-adjustable-sensitivity-and-time-delay-electroprobe-ev/">DIN Rail Mounted Level Controller with Adjustable Sensitivity and Time Delay &#8211; Electroprobe EV</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></content:encoded>
										</item>
		<item>
		<title>DIN Rail Mounted Level Controller with Alarms &#8211; Electroprobe DB</title>
		<link>https://mac3uk.com/product/din-rail-mounted-level-controller-with-alarms-electroprobe-db/</link>
				<pubDate>Mon, 03 Sep 2018 09:29:43 +0000</pubDate>
		<dc:creator><![CDATA[Jim]]></dc:creator>
		
		<guid isPermaLink="false">https://mac3uk.com/?post_type=product&#038;p=349</guid>
				<description><![CDATA[<p>DIN rail mounted (4DIN, 76mm) conductivity probe level controller with external alarm relay.</p>
<p>Available for various supply voltages from 24Vac, 117Vac and 230Vac.</p>
<p> <i class="fa fa-download"></i>User Manual - PDF</p>
<p> <i class="fa fa-download"></i>Brochure - PDF</p>
<h2>Electroprobe Overview Video</h2>
<p><iframe src="https://www.youtube.com/embed/mnOVlX-Xh3A" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/din-rail-mounted-level-controller-with-alarms-electroprobe-db/">DIN Rail Mounted Level Controller with Alarms &#8211; Electroprobe DB</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></description>
								<content:encoded><![CDATA[<h4><i class="fa fa-wrench"></i> Application</h4>
<p>DIN rail mounted (4DIN, 76mm) conductivity probe level controller with external alarm relay. Available for various supply voltages from 24Vac, 117Vac and 230Vac.</p>
<p>Mac3 Electroprobe DB is a multifunctional level controller with 4 functions:</p>
<ul>
<li><strong>Differential Fill/Drain Function</strong>, activates a relay output to maintain the level between two probes set at different heights. The relay only changes state when either the upper probe becomes immersed or the lower probe becomes dry, allowing the water level to move between but not exceed the area between the two level probes.</li>
<li><strong>High Level Alarm</strong> &#8211; Activates the alarm relay when a probe is immersed.</li>
<li><strong>Low Level Alarm</strong> &#8211; Activates the alarm relay when a probe becomes dry.</li>
<li><strong>Single Point Control</strong> &#8211; Switches a 2nd control relay when a probe is immersed or dry. This can be used to inhibit/enable the device attached to the differential relay, or to enable an additional device.</li>
</ul>
<h4><i class="fa fa-plus"></i> Advantages</h4>
<p>All functions can operate at the same time using up to 7 probes and are independent of each other in operation.</p>
<h4><i class="fa fa-thumbs-up"></i> Benefits</h4>
<ul>
<li>Ideal for OEM integration or control panel building</li>
<li>Uses conductivity probes with no moving parts</li>
<li>Adjustable probe sensitivity (0-20KΩ)</li>
<li>External alarm relay</li>
<li>Non-voltage relay outputs rated 250VAC 5A(AC1) 2A(AC3)</li>
</ul>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/din-rail-mounted-level-controller-with-alarms-electroprobe-db/">DIN Rail Mounted Level Controller with Alarms &#8211; Electroprobe DB</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></content:encoded>
										</item>
		<item>
		<title>DIN Rail Mounted Rainwater Level Controller &#8211; RainControl</title>
		<link>https://mac3uk.com/product/rainwater-level-controller-raincontrol/</link>
				<pubDate>Tue, 28 Aug 2018 08:38:00 +0000</pubDate>
		<dc:creator><![CDATA[Jim]]></dc:creator>
		
		<guid isPermaLink="false">https://mac3uk.com/?post_type=product&#038;p=338</guid>
				<description><![CDATA[<p>DIN rail mounted mains cold water back-up and level display system.</p>
<p><strong>A pressure probe is not included (contact us for options).</strong></p>
<p><i class="fa fa-download"></i>User Manual - PDF</p>
<p><i class="fa fa-download"></i>Brochure - PDF</p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/rainwater-level-controller-raincontrol/">DIN Rail Mounted Rainwater Level Controller &#8211; RainControl</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></description>
								<content:encoded><![CDATA[<h4><i class="fa fa-wrench"></i> Application</h4>
<p>DIN rail-mounted unit, that measures a rainwater tank level using a submerged pressure sensor (not included) and either tops up with a measured amount of mains water (direct systems with submerged pump), or opens a 3-way motorized valve (indoor break tank &amp; pump systems) when required.</p>
<p>When a low-level threshold is reached, RainControl opens a solenoid or motorised valve to supply mains water until a high-level threshold is reached. After this, RainControl de-activates the output and reverts to level display mode.</p>
<h4><i class="fa fa-plus"></i> Advantages</h4>
<p>An anti-blocking timer function allows the valve to be scheduled to open periodically regardless of the tank level, to prevent jamming.</p>
<p>All of the thresholds for high and low water levels can be set by the installer, calibrating the unit to whatever installation the unit is connected to.</p>
<h4><i class="fa fa-thumbs-up"></i> Benefits</h4>
<ul>
<li>DIN rail mounted.</li>
<li>Ideal for OEM systems and panel building.</li>
<li>Customisable operating parameters.</li>
<li>Accurate LCD level display and mains cold water top-up/back-up function.</li>
<li>Level measurement by submerged pressure sensor (not included).</li>
<li>No moving parts.</li>
</ul>
<h4>FAQs</h4>
<p>Read more about the RainControl Tank Level Controller on our RainController FAQ page.</p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/rainwater-level-controller-raincontrol/">DIN Rail Mounted Rainwater Level Controller &#8211; RainControl</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></content:encoded>
										</item>
		<item>
		<title>1 or 2 Pump Controller &#8211; Direct On-line Starter &#8211; Quadri</title>
		<link>https://mac3uk.com/product/1-or-2-pump-controller-direct-on-line-starter-quadri/</link>
				<pubDate>Wed, 22 Aug 2018 14:17:32 +0000</pubDate>
		<dc:creator><![CDATA[Jim]]></dc:creator>
		
		<guid isPermaLink="false">https://mac3uk.com/?post_type=product&#038;p=273</guid>
				<description><![CDATA[<p>The Quadri is a direct on-line starter and pump controller for use with Single and three phase systems.</p>
<p>It is able to control up to two pumps and balance the load between them for Boosting, Storage or Sewage pump systems.</p>
<p>Functions in either an automatic or manual configuration.</p>
<p> User Manual (Single Phase for 1 Pump) - PDF</p>
<p> User Manual (Single Phase for 2 Pumps) - PDF</p>
<p> User Manual (Three Phase for 1 Pump) - PDF</p>
<p> User Manual (Three Phase for 2 Pumps) - PDF</p>
<p> Brochure - PDF</p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/1-or-2-pump-controller-direct-on-line-starter-quadri/">1 or 2 Pump Controller &#8211; Direct On-line Starter &#8211; Quadri</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></description>
								<content:encoded><![CDATA[<h4><i class="fa fa-wrench"></i> Application</h4>
<p>Pump Control/Protection Panel of a single submersible pump. Options for Single Phase or Three Phase. This Controller can function in either an automatic or manual configuration.</p>
<p>The Quadri can control up to two pumps, and is able to balance the workload by alternating the starts of each pump (unless demand requires both pumps be activated simultaneously). The Quadri uses float switches/level probes and/or pressure switches to determine if single or both pumps are required.</p>
<p>The Quadri can run in three modes:</p>
<ul>
<li>Boosting</li>
<li>Storage</li>
<li>Sewage</li>
</ul>
<p><strong>Boosting</strong> allows the Quadri to function with a pressure boosting system, using both probes and pressure switches to monitor and run pumps when a pressure or level drop is detected.</p>
<p><strong>Storage</strong> allows the Quadri to monitor the levels in two tanks, and function as a level controller.</p>
<p><strong>Sewage</strong> allows the Quadri to use float switches to determine levels inside a tank and pump according to the parameters set by the installer.</p>
<h4><i class="fa fa-plus"></i> Advantages</h4>
<p>Operational parameters can be viewed n the LED’s and edited on the potentiometers on the circuit board.<br />
This allows the Quadri to display system information such as:</p>
<ul>
<li>The operational status of the motor</li>
<li>Error messages</li>
<li>Defined parameters of operation</li>
</ul>
<h4><i class="fa fa-thumbs-up"></i> Benefits</h4>
<ul>
<li>Pump Balancing</li>
<li>Adjustable Settings</li>
<li>Durable ABS Contruction</li>
<li>High Quality Electronics</li>
<li>IP55</li>
</ul>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/1-or-2-pump-controller-direct-on-line-starter-quadri/">1 or 2 Pump Controller &#8211; Direct On-line Starter &#8211; Quadri</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></content:encoded>
										</item>
		<item>
		<title>Voltage Control &#8211; 3F Control</title>
		<link>https://mac3uk.com/product/voltage-control-3f-control/</link>
				<pubDate>Wed, 04 Jul 2018 12:36:19 +0000</pubDate>
		<dc:creator><![CDATA[Jim]]></dc:creator>
		
		<guid isPermaLink="false">https://mac3uk.com/?post_type=product&#038;p=241</guid>
				<description><![CDATA[<p>The Mac3 3F Controls are a DIN socket mounted single phase, adjustable under-voltage monitoring and protection relays intended for use in control panels.</p>
<p>Mod.22 is Single Phase.</p>
<p>Mod.33 is three phase with additional phase loss protection.</p>
<p><i class="fa fa-download"></i> User Manual - PDF</p>
<p><i class="fa fa-download"></i> Brochure - PDF</p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/voltage-control-3f-control/">Voltage Control &#8211; 3F Control</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></description>
								<content:encoded><![CDATA[<p>&nbsp;</p>
<h4><i class="fa fa-wrench"></i> Application</h4>
<p>The Mac3 3F Controls are a DIN socket mounted, adjustable under-voltage monitoring and protection relays intended for use in control panels.</p>
<p>Mod.22 is Single Phase.</p>
<p>Mod.33 is Three phase with additional phase loss protection.</p>
<h4><i class="fa fa-plus"></i> Advantages</h4>
<p>Low voltage leads to increased current and excess heat generation in induction motors causing damage or reducing the life of coils and bearings. Low voltage may be caused by poorly functioning generators, and other temporary power systems, inadequate cable sizing especially temporary wiring or wiring in remote locations such as outbuildings, or poorly specified over-current protection allowing a circuit to be loaded by other appliances beyond it’s proper capacity. Hence under-voltage protection helps to protect important appliances from premature failure avoiding expensive down-time.</p>
<h4><i class="fa fa-thumbs-up"></i> Benefits</h4>
<p>Both 3F Controls isolate the system if:</p>
<ul>
<li>The system voltage drops up to 2.5% of the set value for more than 2 seconds, or</li>
<li>The system voltage drops more than 2.5% of the set value at all.</li>
</ul>
<p>A 2 second delay, built into the relay, ensures temporary voltage drops in the electricity supply do not trip the system, while preventing potential pump damage should the condition continue.</p>
<p>The 3F Control Mod. 33 also monitors for phase loss and incorrect phase rotation. This can be due to wiring the phases incorrectly or issues arising from the supply itself, but either condition will cause the 3F Control Mod. 33 to isolate the system until the error is rectified.</p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/voltage-control-3f-control/">Voltage Control &#8211; 3F Control</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></content:encoded>
										</item>
		<item>
		<title>Single Pump Controller with CosPhi Dry Run Protection &#8211; Quadri CosPhi</title>
		<link>https://mac3uk.com/product/single-pump-controller-with-cosphi-dry-run-protection/</link>
				<pubDate>Mon, 04 Jun 2018 14:38:46 +0000</pubDate>
		<dc:creator><![CDATA[Jim]]></dc:creator>
		
		<guid isPermaLink="false">https://mac3uk.com/?post_type=product&#038;p=214</guid>
				<description><![CDATA[<p>Quadri CosPhi Pump Control/Protection Panel of a single submersible pump. Built-in Dry Run Protection using CosPhi monitoring of the motor itself.</p>
<p>Options for Single Phase or Three Phase. This Controller can function in either an automatic or manual configuration.</p>
<p> User Manual (Single Phase) - PDF</p>
<p> User Manual (Three Phase) - PDF</p>
<p> Brochure - PDF</p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/single-pump-controller-with-cosphi-dry-run-protection/">Single Pump Controller with CosPhi Dry Run Protection &#8211; Quadri CosPhi</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></description>
								<content:encoded><![CDATA[<h4><i class="fa fa-wrench"></i> Application</h4>
<p>Pump Control/Protection Panel of a single submersible pump. Options for Single Phase or Three Phase. This Controller can function in either an automatic or manual configuration.</p>
<p>It can be used with a float switch for drainage and tank filling applications, or with a pressure switch for direct pressure systems.</p>
<h4><i class="fa fa-plus"></i> Advantages</h4>
<p>The Quadri CosPhi utilizes CosPhi monitoring of the motor itself, combined with the use of either a float switch or pressure switch to monitor pump function. The Quadri Dry Control Plus activates the pump when required to maintain pressure in the system. If there is a fault or error with the pump, the Controller will<br />
turn the pump off. The Unit therefore prolongs the overall life of the installation.</p>
<h4><i class="fa fa-thumbs-up"></i> Benefits</h4>
<ul>
<li>No need for level probes it is therefore particularly suitable for deep wells.</li>
<li>Thermal Overload Protection</li>
<li>Over and Under Voltage Protection</li>
<li>Adjustable Settings</li>
<li>Durable ABS Contruction</li>
<li>High Quality Electronics</li>
<li>IP55</li>
</ul>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/single-pump-controller-with-cosphi-dry-run-protection/">Single Pump Controller with CosPhi Dry Run Protection &#8211; Quadri CosPhi</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></content:encoded>
										</item>
	</channel>
</rss>
