<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>QuickStop Valves &#8211; Mac 3 UK</title>
	<atom:link href="https://mac3uk.com/product-category/level-control/quickstop-valves/feed/" rel="self" type="application/rss+xml" />
	<link>https://mac3uk.com</link>
	<description>Water meets Technology</description>
	<lastBuildDate>Tue, 06 Aug 2024 12:57:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<!--Theme by MyThemeShop.com-->
	<item>
		<title>QuickStop Advance &#8211; Adjustable</title>
		<link>https://mac3uk.com/product/quickstop-advance-adjustable/</link>
				<pubDate>Tue, 29 May 2018 13:26:49 +0000</pubDate>
		<dc:creator><![CDATA[Jim]]></dc:creator>
		
		<guid isPermaLink="false">https://mac3uk.com/?post_type=product&#038;p=162</guid>
				<description><![CDATA[<p>QuickStop Advance has a very high flow rate allowing rapid filling with minimal pressure loss. Designed as a replacement to conventional ballcock valves in water tanks to protect booster pumps, the QuickStop goes instantly from fully open to fully closed.</p>
<p>The arm on this Adjustable version can be easily altered by both length and mounting angle to set where the float sits relative to the regulator. Setting these two points allows for precise control of when the regulator is opened or closed by the movement of the float.</p>
<p>BSP Connections from 1/2” to 1 ½”.</p>
<p>Size 1/2” adjustable at point 1: 0 to 30 degrees.<br />
Other sizes adjustable at point 1: 0 to 150 degrees.</p>
<p><i class="fa fa-download"></i>  User Manual - PDF</p>
<p><i class="fa fa-download"></i>  Brochure - PDF</p>
<h2>QuickStop Video Tutorial</h2>
<p><iframe src="https://www.youtube.com/embed/videoseries?list=PLno4FCRkX7VzvtkKGxTVZG9HrxhXvj6MB" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/quickstop-advance-adjustable/">QuickStop Advance &#8211; Adjustable</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></description>
								<content:encoded><![CDATA[<p>&nbsp;</p>
<h4><i class="fa fa-wrench"></i>  Application</h4>
<p>The QuickStop Advance valve can be used in both a passive gravity fed or pumped system. Suitable for filling tanks, cisterns or troughs for livestock. Designed as a replacement to conventional ballcock valves in water tanks to protect booster pumps.</p>
<h4><i class="fa fa-plus"></i>  Advantages</h4>
<p>QuickStop Advance has a very high flow rate allowing rapid filling with minimal pressure loss. The QuickStop goes instantly from fully open to fully closed.</p>
<p>The arm on this Adjustable version can be easily altered by both length and mounting angle to set where the float sits relative to the regulator. Setting these two points allows for precise control of when the regulator is opened or closed by the movement of the float.</p>
<h4><i class="fa fa-thumbs-up"></i>  Benefits</h4>
<p>This Hydraulically actuated valve is of particular use in pumped systems as it prevents repeated stop/start cycling of pumps when filling tanks or cisterns. The valve allows a high flow rate to the pump immediately. The potential for damage to the pump from overheating or running dry is therefore prevented. The efficiency and running costs of the system are reduced by not having a pump running at full power while delivering a low volume of water.</p>
<p>BSP Connections from 1/2” to 1 ½”.</p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/quickstop-advance-adjustable/">QuickStop Advance &#8211; Adjustable</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></content:encoded>
										</item>
		<item>
		<title>QuickStop Advance &#8211; Standard</title>
		<link>https://mac3uk.com/product/hydraulic-valve-quickstop-standard/</link>
				<pubDate>Fri, 25 May 2018 14:44:44 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
		
		<guid isPermaLink="false">https://mac3uk.com/?post_type=product&#038;p=113</guid>
				<description><![CDATA[<p>QuickStop Advance has a very high flow rate allowing rapid filling with minimal pressure loss. Designed as a replacement to conventional ballcock valves in water tanks to protect booster pumps, the QuickStop goes instantly from fully open to fully closed.</p>
<p>Adjustable version: <a href="https://mac3uk.com/product/quickstop-advance-adjustable/">https://mac3uk.com/product/quickstop-advance-adjustable/</a></p>
<p>BSP Connections from 1/2” to 1 ½”.</p>
<p><i class="fa fa-download"></i>  User Manual - PDF</p>
<p><i class="fa fa-download"></i>  Brochure - PDF</p>
<h2>QuickStop Video Tutorial</h2>
<p>Note the video mainly shows the "Adjustable" quickstop not the "Standard".<br />
<iframe src="https://www.youtube.com/embed/videoseries?list=PLno4FCRkX7VzvtkKGxTVZG9HrxhXvj6MB" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/hydraulic-valve-quickstop-standard/">QuickStop Advance &#8211; Standard</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></description>
								<content:encoded><![CDATA[<p>&nbsp;</p>
<h4><i class="fa fa-wrench"></i>  Application</h4>
<p>The QuickStop Advance valve can be used in both a passive gravity fed or pumped system. Suitable for filling tanks, cisterns or troughs for livestock. Designed as a replacement to conventional ballcock valves in water tanks to protect booster pumps.</p>
<h4><i class="fa fa-plus"></i>  Advantages</h4>
<p>QuickStop Advance has a very high flow rate allowing rapid filling with minimal pressure loss. The QuickStop goes instantly from fully open to fully closed.</p>
<h4><i class="fa fa-thumbs-up"></i>  Benefits</h4>
<p>This Hydraulically actuated valve is of particular use in pumped systems as it prevents repeated stop/start cycling of pumps when filling tanks or cisterns. The valve allows a high flow rate to the pump immediately. The potential for damage to the pump from overheating or running dry is therefore prevented. The efficiency and running costs of the system are reduced by not having a pump running at full power while delivering a low volume of water.</p>
<p>BSP Connections from 1/2” to 1 ½”.</p>
<p>The post <a rel="nofollow" href="https://mac3uk.com/product/hydraulic-valve-quickstop-standard/">QuickStop Advance &#8211; Standard</a> appeared first on <a rel="nofollow" href="https://mac3uk.com">Mac 3 UK</a>.</p>
]]></content:encoded>